Onderdelen: Voedingen: DIN-RAIL 48V/10A, 480W POWER SUPPLY
DIN-RAIL 48V/10A, 480W POWER SUPPLY
 
DIN-RAIL 48V/10A, 480W POWER SUPPLY
145,20-incl. BTW
Voor 14u bestellen, morgen thuis geleverd
Voor 14u bestellen, vanaf morgen afhalen in de winkel

EAN: 5902135138144
MPN: DRP048V480W1BN
Merk: Noname

Toon volledige specificatiesVerberg volledige specificaties

Model: OEM LPS333

Features

  • Universal AC input voltage range
  • Power will not de-rate for the entire input voltage range
  • Power Boost of 150% for 5 seconds and 200% for 2 seconds
  • Full corrosion resistant aluminium casing
  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • Extreme low temperature cold start at -40°C
  • Conformal coating on PCBAs to protect against common dust and chemical pollutants
  • Hazardous Locations approval to ATEX and Class I, Div 2 (DRP048V480W1BA)
  • Certified according to IEC/EN/UL 62368-1

Specifications

Input Ratings / Characteristics

  • Nominal Input Voltage: 100-240Vac
  • Input Voltage Range: 85-264Vac
  • Nominal Input Frequency: 50-60Hz
  • Input Frequency Range: 47-63Hz
  • DC Input Voltage Range*: 120-375Vdc
  • Input Current: < 5.00A @ 115Vac, < 3.00A @ 230Vac
  • Efficiency at 100% Load: > 91.0% @ 115Vac, > 93.0% @ 230Vac
  • Max Power Dissipation:
    • 0% load < 5W @ 115Vac & 230Vac
    • 100% load < 46.5W @ 115Vac, < 34.5W @ 230Vac
  • Max Inrush Current: < 35A @ 115Vac & 230Vac
  • Power Factor at 100% Load: > 0.96 @ 115Vac, > 0.90 @ 230Vac
  • Leakage Current: < 3mA @ 240Vac

*Fulfills test conditions for DC input. Safety approval for DC input can be obtained upon request.

Output Ratings / Characteristics**

  • Nominal Output Voltage: 48Vdc
  • Factory Set Point Tolerance: 48Vdc ± 1%
  • Output Voltage Adjustment Range: 48-56Vdc
  • Output Current:
    • 10.0A (continuously operating at 48V)
    • 15.0A (Power Boost for 5 seconds at 48V, refer to the details in the Functions section)
  • Output Power:
    • 480W (continuously operating at 48V)
    • 720W (Power Boost for 5 seconds at 48V, refer to the details in the Functions section)
  • Line Regulation: < 0.5% (@ 85-264Vac input, 100% load)
  • Load Regulation: < 1.0% (@ 85-264Vac input, 0-100% load)
  • PARD*** (20MHz): < 200mVpp
  • Rise Time: < 350ms @ nominal input (100% load)
  • Start-up Time: < 1,500ms @ nominal input (100% load)
  • Hold-up Time: > 20ms @ 115Vac & 230Vac (100% load)
  • Dynamic Response (Overshoot & Undershoot O/P Voltage):
    • ± 2% @ 85-264Vac input, 10-90% load
    • (Slew Rate: 0.1A/?s, 50% duty cycle @ 5Hz to 1KHz)
  • Start-up with Capacitive Loads: 10,000µF Max

**For power de-rating from > 50°C to 75°C, see power de-rating on page 3.
*** PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1?F ceramic capacitor & 47?F electrolytic capacitor.

Mechanical

  • Case Cover / Chassis: Aluminium

Dimensions (L x W x D): 121 x 144 x 118.6 mm (4.76 x 5.67 x 4.67 inch)

  • Unit Weight: 1.37 kg (3.02 lb)
  • Indicator: Green LED: DC OK
  • Cooling System: Convection
  • Terminal:
    • Input 3 Pins (Rated 300V/30A)
    • Output 4 Pins (Rated 300V/30A)
  • Wire:
    • Input AWG 18-10
    • Output AWG 16-10
  • Mounting Rail: Standard TS35 DIN Rail in accordance with EN 60715
  • Noise (1 Meter from power supply): Sound Pressure Level (SPL) < 25dBA

Environment

  • Surrounding Air Temperature:
    • Operating -25°C to +75°C (Cold Start at -40°C)
    • Storage: -40°C to +85°C
  • Power De-rating Temperature:
    • > 50°C de-rate power by 2.5% / °C,
    • > 70°C de-rate power by 5% / °C
  • Operating Humidity: 5 to 95% RH (Non-Condensing)
  • Operating Altitude: 0 to 2,500 Meters (8,200 ft.)
  • Shock Test: Non-Operating: IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 1 time per direction, 2 times in total
  • Vibration Non-Operating: IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction
  • Bump Test: Operating: IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
  • Over Voltage Category: III According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part)
  • Pollution Degree: 2

Protections

  • Overvoltage:
    • < 57V, SELV Output, Hiccup Mode,
    • Non-Latching (Auto-Recovery)
  • Overload / Overcurrent:
    • > 150% of rated load current, Hiccup Mode,
    • Non-Latching (Auto-Recovery)
  • Over Temperature:
    • < 80°C Surrounding Air Temperature @ 100% load,
    • Non-Latching (Auto-Recovery)
  • Short Circuit: Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
  • Transient Surge Voltage Protection: MOV (Metal Oxide Varistor)
  • Internal Fuse at L pin: T8AH
  • Degree of Protection: IP20
  • Protection Against Shock: Class I with PE* connection

*PE: Primary Earth

Reliability Data

  • MTBF:
    • > 500,000 hrs. as per Telcordia SR-332
    • I/P: 115Vac, O/P: 100% load, Ta: 25°C
  • Expected Cap Life Time: 10 years (115Vac & 230Vac, 50% load @ 40°C)

Safety Standards / Directives

  • Electrical Equipment of Machines: EN 60204-1 (over voltage category III)
  • Electrical Equipment for Use in Electrical Power Installations: IEC/EN 62477-1 / IEC 62103
  • Safety Entry Low Voltage: PELV* (EN 60204-1), SELV (EN 60950-1)
  • Overvoltage on Telecommunication Networks: TNV-1 circuit
  • Electrical Safety:
  • SIQ Bauart: EN 60950-1, EN 62368-1
  • UL/cUL recognized:
    • UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395)
    • UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395)
  • CB scheme: IEC 60950-1, IEC 62368-1
  • Industrial Control Equipment:
  • UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)
  • CSA: CSA C22.2 No. 107.1-01 (File No. 181564)
  • Hazardous Location / ATEX: (For DRP048V480W1BA)
    • cCSAus: CSA C22.2 No. 213-M1987 and ANSI / ISA 12.12.01:2007
    • [Class I, Division 2, Group A, B, C, D T4, Ta= -25°C to +75°C (Vertical: > +50°C derating)]
  • ATEX:
    • EN 60079-0:2009, EN 60079-15:2010 [ II 3G Ex nA nC IIC
    • T4 Gc, Ta= -25°C to +75°C (Vertical: > +50°C derating)]
    • Certificate No. EPS 12 ATEX 1 491 X
  • CE: In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
    For DRP048V480W1BA: In conformance with Equipment for explosive atmospheres (ATEX) directive 2014/34/EU
  • Galvanic Isolation:
    • Input to Output 4.0KVac
    • Input to Ground 1.5KVac
    • Output to Ground 1.5KVac

*Output must be earthed in the final unit in order to comply with PELV requirements according to standard EN 60204-1

EMC

  • Emissions (CE & RE):
    • Generic Standards: CISPR 32, EN 55032, CISPR 11,
    • EN 55011, FCC Title 47: Class B
  • Component Power Supply for General Use: EN 61204-3
  • Immunity: Generic Standards: EN 55024, EN 61000-6-2
  • Electrostatic Discharge IEC 61000-4-2:
    • Level 4 Criteria A1)
    • Air Discharge: 15kV
    • Contact Discharge: 8kV
  • Radiated Field: IEC 61000-4-3:
    • Level 3 Criteria A1)
    • 80MHz-1GHz, 10V/M, 80% modulation (1kHz)
  • Electrical Fast Transient / Burst: IEC 61000-4-4:
    • Level 3 Criteria A1)
    • 2kV
  • Surge: IEC 61000-4-5:
    • Level 3 Criteria A1)
    • Common Mode3) : 2kV
    • Differential Mode4): 1kV
  • Conducted: IEC 61000-4-6:
    • Level 3 Criteria A1)
    • 150kHz-80MHz, 10Vrms
  • Power Frequency Magnetic Fields: IEC 61000-4-8
    • Criteria A1)
    • 10A/Meter
  • Voltage Dips and Interruptions: IEC 61000-4-11
    • 0% of 100Vac, 20ms     Criteria A1)
    • 40% of 100Vac, 200ms  Criteria B2)
    • 70% of 100Vac, 500ms  Criteria B2)
    • 0% of 100Vac, 5000ms  Criteria B2)
    • 0% of 240Vac, 20ms      Criteria A1)
    • 40% of 240Vac, 200ms  Criteria A1)
    • 70% of 240Vac, 500ms  Criteria A1)
    • 0% of 240Vac, 5000ms  Criteria B2)

 

  • Low Energy Pulse Test: (Ring Wave): IEC 61000-4-12
    • Level 3 Criteria A1)
    • Common Mode3): 2kV
    • Differential Mode4): 1Kv
  • Harmonic Current Emission: IEC/EN 61000-3-2, Class A
  • Voltage Fluctuation and Flicker: IEC/EN 61000-3-3

1) Criteria A: Normal performance within the specification limits
2) Criteria B: Temporary degradation or loss of function which is self-recoverable
3) Asymmetrical: Common mode (Line to earth)
4) Symmetrical: Differential mode (Line to line)


Voor 14u bestellen = morgen thuis geleverd of vanaf morgen afhalen in de winkel*
*: de levertermijnen zijn indicaties & hangen af van leveranciers en transportfirmas

145.20 Gratis verzending vanaf € 50