IPsec: IKEv1, IKEv2, supports up to 4 x VPN IPsec tunnels (instances), with 5 encryption methods (DES, 3DES, AES128, AES192, AES256)
GRE: GRE tunnel
PPTP, L2TP: Client/Server services can run simultaneously
Stunnel: Proxy designed to add TLS encryption functionality to existing clients and servers without any changes in the programs' code
SSTP: SSTP client instance support
ZeroTier: ZeroTier VPN
WireGuard: WireGuard VPN client and server support
MODBUS
MODBUS TCP SLAVE
ID filtering: Respond to one ID in range [1;255] or any
Allow Remote Access: Allow access through WAN
Custom registers: Modbus TCP custom register block requests, which read/write to a file inside the router, and can be used to extend Modbus TCP Slave functionality
Cloud of Things: Allows monitoring of: Device data, Mobile data, Network info, Availability
ThingWorx: Allows monitoring of: WAN Type, WAN IP Mobile Operator Name, Mobile Signal Strength, Mobile Network Type
Cumulocity: Allows monitoring of: Device Model, Revision and Serial Number, Mobile Cell ID, ICCID, IMEI, Connection Type, Operator, Signal Strength, WAN Type and IP
Azure IoT Hub: Can send device IP, Number of bytes send/received/ 3G connection state, Network link state, IMEI, ICCID, Model, Manufacturer, Serial,
Revision, IMSI, Sim State, PIN state, GSM signal, WCDMA RSCP WCDMA EC/IO, LTE RSRP, LTE SINR, LTE RSRQ, CELL ID,
Operator, Operator number, Connection type, Temperature, PIN count to Azure IoT Hub server
SYSTEM CHARACTERISTICS
CPU: Atheros Hornet, MIPS 24Kc, 400 MHz
RAM: 64 MB, DDR2
FLASH storage: 16 MB, SPI Flash
FIRMWARE / CONFIGURATION
WEB UI: Update FW from file, check FW on server, configuration profiles, configuration backup, restore point
FOTA: Update FW/configuration from server
RMS: Update FW/configuration for multiple devices
Keep settings: Update FW without losing current configuration
FIRMWARE CUSTOMIZATION
Operating system: RutOS (OpenWrt based Linux OS)
Supported languages: Busybox shell, Lua, C, C++
Development tools: SDK package with built environment provided
INPUT/OUTPUT
Input: 1 x Digital input, 0 - 6 V detected as logic low, 8 - 30 V detected as logic high
Output: 1 x Digital open collector output, max output 30 V, 300 mA
Events: SMS, EMAIL, RMS
POWER
Connector: 4 pin industrial DC power socket
Input voltage range: 9 – 30 VDC, reverse polarity protection, surge protection >33 VDC 10us max
PoE (passive): Passive PoE over spare pairs (available from HW revision 0007 and batch number 0010). Possibility to power up through LAN port, not compatible with IEEE802.3af, 802.3at and 802.3bt