Onderdelen: Voedingen: DIN-RAIL 48V/2.5A, 120W POWER SUPPLY
DIN-RAIL 48V/2.5A, 120W POWER SUPPLY
 
DIN-RAIL 48V/2.5A, 120W POWER SUPPLY
49-incl. BTW
Voor 14u bestellen, morgen thuis geleverd
Voor 14u bestellen, vanaf morgen afhalen in de winkel

EAN: 5902135100639
MPN: DRP048V060W1BN
Merk: Noname

Toon volledige specificatiesVerberg volledige specificaties

Model: OEM LPS330

Features

  • Universal AC input voltage range
  • Power will not de-rate for the entire input voltage range
  • Power Boost of 150% for 5 seconds
  • Full corrosion resistant aluminium casing
  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • Extreme low temperature cold start at -40°C
  • Conformal coating on PCBAs to protect against common dust and chemical pollutants
  • Hazardous Locations approval to ATEX and Class I, Div 2 (DRP048V060W1BA)
  • Certified according to IEC/EN/UL 62368-1

Specifications

Input Ratings / Characteristics

  • Nominal Input Voltage: 100-240Vac
  • Input Voltage Range: 85-264Vac
  • Nominal Input Frequency: 50-60Hz
  • Input Frequency Range: 47-63Hz
  • DC Input Voltage Range: 120-375Vdc
  • Input Current: < 1.40A @ 115Vac, < 0.80A @ 230Vac
  • Efficiency at 100% Load: > 91.0% @ 115Vac, > 92.0% @ 230Vac
  • Max Power Dissipation:
    • 0% load: < 0.5W @ 115Vac & 230Vac
    • 100% load: < 5.9W @ 115Vac, < 5.2W @ 230Vac
  • Max Inrush Current (Cold Start): < 20A @ 115Vac, < 35A @ 230Vac
  • Leakage Current: < 1mA @ 240Vac

Output Ratings / Characteristics

  • Nominal Output Voltage: 48Vdc
  • Factory Set Point Tolerance: 48Vdc ± 1%
  • Output Voltage Adjustment Range: 48-56Vdc
  • Output Current:
    • 1.25A (continuously operating at 48V)
    • 1.875A (Power Boost for 5 seconds at 48V, refer to the details in the Functions section)
  • Output Power:
    • 60W (continuously operating at 48V)
    • 90W (Power Boost for 5 seconds at 48V, refer to the details in the Functions section)
  • Line Regulation: < 0.5% (@ 85-264Vac input, 100% load)
  • Load Regulation: < 1.0% (@ 85-264Vac input, 0-100% load)
  • PARD*** (20MHz): < 200mVpp
  • Rise Time: < 100ms @ nominal input (100% load)
  • Start-up Time: < 1,500ms @ nominal input (100% load)
  • Hold-up Time:
    • > 20ms @ 115Vac,
    • > 125ms @ 230Vac (100% load)
  • Dynamic Response (Overshoot & Undershoot O/P Voltage): ± 2% @ 85-264Vac input, 0-100% load (Slew Rate: 0.1A/?s, 50% duty cycle @ 5Hz)
  • Start-up with Capacitive Loads: 5,000µF Max

Mechanical

  • Case Cover / Chassis: Aluminium
  • Dimensions (L x W x D): 121 x 32 x 125 mm (4.76 x 1.26 x 4.92 inch)
  • Unit Weight: 0.38 kg (0.84 lb)
  • Indicator: Green: LED DC OK
  • Cooling System: Convection
  • Terminal:
    • Input: 3 Pins (Rated 300V/15A)
    • Output: 2 Pins (Rated 300V/15A)
  • Wire: Input / Output: AWG 20-12
  • Mounting Rail: Standard TS35 DIN Rail in accordance with EN 60715
  • Noise (1 Meter from power supply): Sound Pressure Level (SPL) < 40dBA

Environment

  • Surrounding Air Temperature:
    • Operating: -25°C to +80°C (Cold Start at -40°C)
    • Storage: -40°C to +85°C
  • Power De-rating:
    • Vertical Mounting: > 50°C de-rate power by 2.5% / °C
    • Horizontal Mounting: > 50°C de-rate power by 2.5% / °C
  • Operating Humidity: 5 to 95% RH (Non-Condensing)
  • Operating Altitude: 0 to 2,500 Meters (8,200 ft.)
  • Shock Test: Non-Operating: IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 1 time per direction, 2 times in total
  • Vibration: Non-Operating: IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction
  • Bump Test: Operating: IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
  • Over Voltage Category: III According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part)
  • Pollution Degree: 2

Protections

  • Overvoltage: < 57V, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery)
  • Overload / Overcurrent: > 150% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
  • Over Temperature: < 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
  • Short Circuit: Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
  • Internal Fuse at L pin: T3.15AH
  • Degree of Protection: IP20
  • Protection Against Shock: Class I with PE* connection (*PE: Primary Earth)

Reliability Data

  • MTBF: > 800,000 hrs. as per Telcordia SR-332 I/P: 115Vac, O/P: 100% load, Ta: 25°C
  • Expected Cap Life Time: 10 years (115Vac & 230Vac, 50% load @ 40°C)

Safety Standards / Directives

  • Electrical Equipment of Machines: EN 60204-1 (over voltage category III)
  • Electrical Equipment for Use in Electrical Power Installations: IEC/EN 62477-1 / IEC 62103
  • Safety Entry Low Voltage: PELV* (EN 60204-1), SELV (EN 60950-1)
  • Electrical Safety:
    • SIQ Bauart: EN 60950-1, EN 62368-1
    • UL/cUL recognized:
      • UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395)
      • UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395)
    • CB scheme: IEC 60950-1, IEC 62368-1
  • Industrial Control Equipment:
    • UL/cUL listed UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)
    • CSA: CSA C22.2 No. 107.1-01 (File No. 181564)
  • Hazardous Location / ATEX (For DRP048V060W1BA):
    • cCSAus: CSA C22.2 No. 213-M1987 and ANSI / ISA 12.12.01:2007 [Class I, Division 2, Group A, B, C, D T4, Ta= -25°C to +80°C (> +50°C derating)]
    • ATEX: EN 60079-0:2009, EN 60079-15:2010 [ II 3G Ex nA nC IIC T4 Gc, Ta= -25°C to +80°C (> +50°C derating)]
    • Certificate No. EPS 12 ATEX 1 491 X
  • CE: In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
    For DRP048V060W1BA: In conformance with Equipment for explosive atmospheres (ATEX) directive 2014/34/EU

Galvanic

  • Isolation Input to Output 4.0KVac
  • Input to Ground 1.5KVac
  • Output to Ground 1.5KVac

Voor 14u bestellen = morgen thuis geleverd of vanaf morgen afhalen in de winkel*
*: de levertermijnen zijn indicaties & hangen af van leveranciers en transportfirmas

49.00